Warmly welcome you visit our company website! Any inquiry,please contact at Tel/ WhatsApp/ Wechat:0086 151 7249 9955 | 0086 138 7129 7575.
Wuhan Wugao Xigao Electric Co.,LTD
Product list
Contact us:
whwgxg@163.com
Mobile:
0086 15172499955
Mobile:
0086 13871297575
Weixin:
0086 15172499955
QQ:
Add:
No. 58, Guanggu Avenue,Donghu Hi-Tech Development

AC Resonant Test System (For Substation Equipment)

brief introduction:AC Resonant Test System (For Substation Equipment)
AC Resonant Test System (For Substation Equipment)

Introduction

Transformer, GIS, SF6 switch, CT/PT, insulator, bus bar, cable, bushing, and others capacitive devices are the common primary electric equipment. Composed by power control cabinet, excitation transformer, reactor, voltage divider, connects silicon rectifier stack and micro ammeter with the voltage divider, then can finish the DC voltage withstand test.

Features

1.It with smaller volume, lighter weight compared with others reactors which in same voltage class and capacity. With small temperature rise under rated load; strong mechanical strength, good insulation performance, reliable.
2.The capacity of the power control cabinet is high; strong protection function; good output waveform; good stability; multi-function, easy to operate; single phase 220V or three phase 380V are available.
3.Can match different kinds reactors, multifunctional, highly cost effective.

Parameters

Rated output voltage

0~1000kV

Output frequency

30~300Hz

Voltage waveform

Sine wave,distoration≤1.0%

Working form

Full power continuous working time 60min

Quality factor

30~90

Frequency adjustment sensitivity

0.1Hz

Instability

<0.05%

Power supply

Single phase 220V or three phase380V±10%

Frequency: 50Hz±5%

Serial product and application:

Model

Application(10kV~500kV transformer substation AC voltage withstand equipment, frequency: 30~300Hz )

Frequency power source

Resonant reactor

Excitation transformer

Divider

Application

WXTF-50/50/25

3kW

25kV/1A:2 sets
( dry type )

3kVA
( dry type )

50kV

10kV transformer ≤1000kVA
10kVswitch, bus bar, PT,CT, etc.
10kV(300mm2)cable≤1.0km

WXTF-108/108/27

5kW

27kV/1A:4 sets
( dry type )

5kVA
( dry type )

110kV

35kV transformer ≤31500kVA

35kV switch, bus bar, PT,CT, etc.
10kV(300mm2)cable: 2km
35kV (300mm2)cable: 0.5km

WXTF-200/200/50

10kW

50kV/1A:4 sets
( dry type )

10kVA
( dry type )

200kV

110kVtransformer≤ 50000kVA
110kVGIS,PT,CT, etc.(preventive trial)
35kV(300mm2)cable≤1.0km
10kV (300mm2)cable≤2.0km

WXTF-270/270/45

15kW

45kV/1A:6 sets
( dry type )

15kVA
( dry type )

300kV

110kVtransformer≤ 50000kVA
110kVGIS,PT,CT, etc.
35kV(300mm2)cable≤1.2km
10kV (300mm2)cable≤3.0km

WXTF-800/400/50

30kW

50kV/2A:8 sets
( dry type )
100kV/2A:4 sets
(oil immersed)

30kVA
( dry type )
30kA

(oil immersed)

400kV

220kV transformer ≤80000kVA

110kVtransformer≤ 50000kVA
110kV/220kVGIS,PT,CT, etc.
35kV(300mm2)cable≤2.0km
110kV (300mm2)cable≤0.7km

WXTF-1600/800/200

60kW

200kV/2A:4 sets
(oil immersed)

60kVA
( dry type )

800kV

220kV transformer ≤80000kVA

110kVtransformer≤ 50000kVA
500kVGIS,PT,CT, etc.
220kVswitch,GIS,PT,CT, etc.
110kV(400mm2) cable≤1.5km
220kV (400mm2) cable≤1.0km


Note: can make the solution according the parameters of the measured equipment